Q. How do PUMPWATCH Measures work?
A. The measure is eveled with the integrated spirit level and screw adjustment on the trolley. After the measure is filled with the test volume (for example 20 litres), a control valve is opened which allows fuel exceeding 99% of the test volume (19.98 litres) to flow into the integrated measurement tube. The valve “freezes” the measurement. After the reading is taken, the measure is wheeled to the discharge point where the measure is emptied through the attached hose. When the flow has ended, the valve-controlled drainage period can include time wheeling the pump back for the next test. How to use a CFX99 Series Test Measure - video How to use a CFX99 Series Test Measure - Printed Instructions More Frequently Asked Questions |